WAFA UNITED · GARBAGE CHUTE SYSTEMS

Garbage Chutes

Stainless-steel garbage chute systems that carry waste from upper floors to a central collection room — clean, hygienic and safe for residential and commercial towers, hospitals and hotels.

A COMPLETE SYSTEM

A clean, safe way to remove waste from multi-storey buildings

Trash, linen and recycling chutes are a simple, low-cost and efficient way to move waste and soiled linen from upper floors to a central discharge room on a lower floor. Each system combines fire-rated intake doors, interlocking, cleaning and sanitizing units, ventilation, sound dampening and fire control — and we handle supply, installation and maintenance from planning to handover.

Our chutes meet the most stringent environmental health and safety requirements, and their integrated design has made them widely used around the world.

Complete garbage chute system from the floors down to the collection room
1.5hr

UL 10B fire-rated intake doors

304/316SS

Stainless steel resistant to moisture and acids

350–1000mm

Standard diameters, or built to drawings

NFPA-82

Complies with building codes and ASTM standards

SYSTEM COMPONENTS

Everything the chute needs, in one system

Regular Chute Section
01

Regular Chute Section

  • Cut from flat sheet and machine-rolled into an accurate cylinder
  • Welded vertical seams for smooth, watertight joints
  • Smooth interior with no projections to impede refuse flow
  • Beading ribs for strength and better sealing
  • Sound-dampening coating to reduce noise and vibration
Intake Chute Section
02

Intake Chute Section

  • An opening on each floor with a throat matched to the intake door
  • Smooth, projection-free interior
  • Beading ribs and sound-dampening coating
  • Throat fully welded and polished
Offset Chute (Elbow)
03

Offset Chute (Elbow)

  • Double bends, 3.0 mm thick for impact and wear resistance
  • 4 ft centerline length or longer per site
  • 15°, 30° or 45° per site
  • Sound-dampening coating; support clips top, middle and bottom
Bottom-Hinged Intake Door
04

Bottom-Hinged Intake Door

  • Hand-operated, self-closing, positive latching
  • UL 1½-hour fire rated, 30 min – 250° max temperature rise
  • Door panel and frame in 1.5 mm 304 stainless steel
  • Fully dismountable while wall-mounted for cleaning and service
  • Intumescent strip for fire rating and sound dampening
Side-Hinged Intake Door
05

Side-Hinged Intake Door

  • Left or right hinged — commonly used for linen chutes
  • T-handle, L-handle (ADA compliant), pull handle or thumb trigger
  • Tubular or square latch; wire-drawn, mirror or bronze finish
  • Frame blank or embossed “Rubbish”, “Soiled Linen” or “Recycle”
  • Accessories: rubber or steel baffle, electrical interlocks, key locks
Support Frame
06

Support Frame

  • 40 × 40 × 5 mm angle steel
  • Hot-dip galvanized for better rust resistance
  • Holes to connect chute sections; rigid, fully welded
  • Custom shapes per building structure, with isolator pads and expansion bolts
Rolling Incline Discharge Door
07

Rolling Incline Discharge Door

  • At the chute bottom, held open by a UL-listed 165°F (74°C) fusible link
  • Closes the chute automatically if fire breaks out in the collection room
  • 3.0 mm SS panel, 1.5 mm frame, collar for 18″–36″ chutes
  • Replaceable link, chain, wheels and panel; inspect monthly
Hopper Discharge Door
08

Hopper Discharge Door

  • Typically for linen chutes; top hinged on chains with a UL fusible link
  • Can extend from the ceiling into the discharge room on pedestals
  • 3.0 mm SS with 1.5 mm frame for 18″–36″ chutes
  • Includes hopper body, frame, pedestals, link, chains and latches
Access Door
09

Access Door

  • Above the top intake, giving access to flushing and sanitizing valves
  • 450×450 or 600×600 mm, side hinged with T-handle
  • 1.5 mm 304 stainless steel, self-closing, positive latching
  • UL 1½-hour fire rated with intumescent strip
Vent Assembly
10

Vent Assembly

  • Dissipates odours, and hot gases if a fire occurs inside the chute
  • NFPA requires a full-diameter vent extending 3 ft above the roof
  • 1.5 mm 304 stainless steel to resist the elements
  • Weather cap, riser, bird & insect screen, flashing cover, exhaust fan, glass-wool curb
MATERIALS & SPECIFICATIONS

Specifications tailored to your project

Materials

We make garbage and linen chutes from 304 or 316 stainless steel, galvanized steel, aluminium-coated steel, or as the customer specifies. We recommend 304/316 stainless: it resists the humidity, acids and alkalis in refuse, has no coating to wear off, and has very high impact strength.

Sheet thickness

1.5 mm (16 ga) — recommended2.0 mm (14 ga)3.0 mm (11 ga)

1.5 mm balances cost and performance.

Standard internal diameters (mm)

14″ = 35018″ = 45020″ = 50024″ = 60028″ = 70030″ = 75032″ = 80036″ = 90040″ = 1000

We also build to customer drawings and special requirements. NFPA requires a minimum diameter of 24″ (600 mm).

Finishes

Stainless 2B finish (chute section)
Stainless 2B finish (chute section)
Door finish — wire drawing
Door finish — wire drawing
Door finish — sand blasting
Door finish — sand blasting
INTAKE DOOR SIZES

Common intake door sizes

Gulf countries market (W × H, mm)

Chute dia.Garbage chute — bottom-hinged doorLinen chute — side-hinged door
18″ (450)400×40015″×15″ (381×381)
20″ (500)450×450 · 400×60018″×18″ (457×457)
24″ (600)400×600 · 450×45021″×21″ (533×533)
28″ (700)400×600 · 450×60021″×21″ (533×533)
30″ (750)400×600 · 450×600 · 600×60024″×24″ (610×610)
36″ (900)600×60024″×24″ (610×610)

Available sizes: 400×500 · 400×600 · 450×600 · 450×450 · 500×500 · 600×600

US & Canada market sizes
Chute dia.Garbage chute — bottom-hinged doorLinen chute — side-hinged door
18″ (450)12″×15″ (305×381)15″×15″ (381×381)
20″ (500)12″×15″ (305×381)18″×18″ (457×457)
24″ (600)15″×18″ (381×457) · 18″×18″ (457×457)18″×18″ (457×457) · 21″×21″ (533×533)
28″ (700)18″×18″ (457×457)21″×21″ (533×533)
30″ (750)21″×18″ (533×457)24″×24″ (610×610)
36″ (900)24″×24″ (610×610)24″×24″ (610×610)

Available sizes: 12″×12″ · 12″×13″ · 12″×15″ · 13″×16″ · 14″×14″ · 14″×17″ · 15″×15″ · 16″×16″

CONTROLS & SAFETY

Interlocking, sorting and the control panel

Interlock — Safe-type

Three lamps on the door frame — green, red and yellow. Green means all doors are ready. Pulling any door open engages the interlock, locks the others and lights red on every floor. Yellow lights during cleaning, disinfection and maintenance.

Interlock — Secure-type

A bi-colour lamp and a push button on the frame. The user presses the button first, which engages the interlock and locks the other doors, then opens the door; red lights on every floor, and also during cleaning and maintenance.

Sorter system (Bi / Tri)

A single chute separates general waste from recyclables (cans, plastic, glass). Residents choose the material on the door keypad and the system diverts it to the right bin or compactor in the basement; the tri-sorter adds one more stream.

The interlock also engages during cleaning, disinfection, maintenance, emergency button and fire alarm — and optionally during brushing, bin replacement or bin full, and smoke detection. Systems are pre-wired for a 120 V or 220 V supply, stepped down to 24 VDC in the main control panel.

Main control panel

Main Control Panel

  • Buttons and indicators for the D&S unit, cleaning, fan, maintenance, emergency and key-lock switch
  • Warning light that flashes and alarms if any function fails
  • Fire alarm integration with the BMS
  • Optional LCD showing the status of each operation and floor
  • Optional integration with compactor, sorter and brushing systems

Electrical system functions

#FunctionDescriptionType
1Interlocking systemWhen one door is open, all other doors lock.Basic
2Disinfection & sanitizingA unit at the top centre sprays water mixed with disinfectant inside the chute for 20 minutes, from the control panel.Basic
3Automatic disinfectionPre-set cycle and run time, with manual start from the panel.Optional
4Cleaning functionA ½″ nozzle in each floor’s throat sprays at 145° into the chute only, not against the doors.Basic
5Automatic cleaningPre-set cycle and run time, with manual start.Optional
6Booster pumpIncreases water pressure.Optional
7FanContinuously drives odours out of the chute.Basic
8Automatic fanPre-set cycle and run time.Optional
9Bi-sorterA keypad on each door lets residents choose the material type; the system diverts it to the right bin or compactor while other doors are disabled.Optional
10Chute-fed compactorBags drop into the compactor and are pushed automatically into one container.Optional
11Smoke & heat detectorWhen smoke or the set temperature is detected, a signal goes to the panel and interlocking engages.Optional
12Automatic cut-off discharge doorLinked to smoke and heat detectors; closes the discharge door automatically and engages interlocking.Optional
13Bin detectionDetects bin-full and bin-replacement.Optional
14Brushing cleaning systemA brush at the top scrubs the inner wall during washing, with water and chemicals, automatically.Optional
MANUFACTURING PARTNER

QDCE — Qingdao Chute Equipment

A specialist waste-management equipment manufacturer with close to ten years in the chute business, ISO 9001 certified and holding a UL 10B fire rating, making its own garbage, laundry, pneumatic and construction chutes and compactors.

  • Metal fabrication in stainless, galvanized steel and aluminium: laser cutting, sheet metal, welding and surface treatment
  • A design team supporting each project from design and production to shop drawings and installation
  • A to-scale 3D drawing of every site to catch installation issues in advance
  • On-site or video after-sales support, and spare parts stocked for ten years after sale

Product range

Garbage chutesLaundry chutesConstruction chutesCompactorsChute-related machinery
OUR PROJECTS

Projects across Saudi Arabia

Hotels, towers and residential compounds in Riyadh, Jeddah and Qiddiya.

View Projects ↗
Park View Hotels
WAFA UNITED

Planning a multi-storey building?

Get a Garbage Chute Quote ↗